Filtration threshold:
—a key concept in air treatment
When determining the effectiveness of a filter medium, the term “filtration threshold” is often used. This value can be nominal or absolute and varies depending on the filter in question. PhotoClean, which develops innovative air decontamination solutions, explains what this means.
Nominal or absolute filtration rating?
The filtration rating refers to the minimum particle size retained by the filter material, typically expressed in micrometers (µm).
As a reminder, the nominal filtration rating means that the filter retains the majority of particles (up to approximately 98%) that are equal to or larger than the specified rating.
As for the absolute filtration rating, it refers to the smallest organism that is captured with an efficiency approaching 100%—hence its name.
Each type of filter has its own threshold…
There are threemain categories of filters, classified according to their efficiency in capturing 0.4 µm particles:
- coarse filters (G) or pre-filters, which have a retention rate of 40%;
- medium-efficiency filters (M), with an efficiency between 40% and 80%;
- fine filters, which have an efficiency of over 80% and generally at least 90%.
In the category of filters with the highest filtration efficiency, we find, for example, HEPA filters, which have an efficiency rate exceeding 99.9%.
Which filter is effective at trapping microorganisms?
The size of microorganisms varies depending on the agent in question. For example, in the food industry, we find:
- yeasts: 10 µm or larger;
- bacteria: 0.1 µm or larger;
- proteins and viruses: between 0.01 and 0.1 µm.
In practice, microfiltration is used to remove bacteria and some viruses—for example, in cold sterilization. In contrast, the dairy and food industry require ultrafiltration, which is capable of retaining particles smaller than 0.1 µm.
In this situation, absolute filtration is the minimum requirement. However, an absolute filter must block 1,000 inert particles to retain a single contaminant.
Filtration Thresholds in Cleanrooms and Gray Rooms
Used in the medical, biological, and food industry sectors, the cleanroom or cleanroom is a space in which the atmosphere is strictly controlled to prevent any environmental contamination. In these industries, the ambient air must be filtered several times per hour, with one-third fresh air introduced to compensate for carbon dioxide emissions from human respiration.
Cleanrooms (NF EN ISO 14644 standard) are classified according to size and permissible particle concentration, ranging from ISO 1 (the “cleanest”) to ISO 9. A particle counter is used to monitor the room’s compliance with the standards.
The filtration threshold in a cleanroom depends on the ISO class in question. For example, an ISO 1 room must contain no more than 10 particles of 0.1 µm/m³ and no more than 2 particles of 0.2 µm/m³. In an ISO 9 room, only particles larger than 0.5 µm are taken into account.
Gray rooms, on the other hand, are used for storing and maintaining equipment used in cleanrooms and serve as a transition between the cleanrooms and untreated areas. The air purity requirements are therefore less stringent in these rooms. However, the use of HEPA or absolute filters is still essential.
For all professionals whose line of work makes it impossible to set up a cleanroom—particularly in the food industry—Photoclean offers an innovative and high-performance industrial UV filtration solution. The advantage? Equipment that continuously filters and destroys only contaminants, without affecting inert particles, resulting in reduced energy consumption and a smaller footprint.